AIR AMPLIFIER STATIONS

MAXIMATOR PLV series air amplifiers are suitable for the compression of pressurised air or nitrogen. The units are capable of increasing normal pressures of 4 bar or 6 bar to the desired final pressures. The Air Amplifiers are operated with normal shop air and are provided with a variety of amplification ratios.

All Air Amplifiers can be supplied with an air control unit comprising a filter, pressure regulator with pressure gauge and an air shut-off valve. The desired operating pressure can be preset by means of the air control unit in correspondence with the different pressure ratios. We can offer you a choice between a standard Air Amplifier Station or a customised solution.

TypeMPLV-2/3L/16barMPLV-4/0,75L/40barSPLV-2/3L/16barSPLV-3/40L/21barGPLV-2/40L/16barGPLV-5/40L/40bar
Pressure ratio
1:21:41:21:3,21:21:5
Outlet P max16 bar40 bar16 bar21 bar16 bar 40 bar
UtilitiesAirAirAirAirAirAir
Max. FlowDepending on the applicationDepending on the applicationDepending on the applicationDepending on the applicationDepending on the applicationDepending on the application
Connection Inlet PLBSP 3/8"BSP 3/8"BSP 3/8"BSP 1/2"BSP 1/2"BSP 1/2"
Connection Outlet BBSP 3/8"BSP 1/4"BSP 3/8"BSP 1/2"BSP 1/2"BSP 1/2"
W x D x H350 x 410 x 240370x 400 x 130345 x 420 x 230850 x 400 x 6600840 x 380 x 640870x 390 x 730
Weight+/- 11kg+/- 5,5kg+/- 15kg+/- 56kg+/- 48.9kg+/- 60,5kg
Air drive pressuremin. 1 bar
max. 8 bar
min. 1 bar
max. 10 bar
min. 1 bar
max. 8 bar
min. 1 bar
max. 10 bar
min. 1 bar
max. 8 bar
min. 1 bar
max. 8 bar